Scenario 3
Implementation of a) a visitable green roof (NBS1 and NBS2) on top of the schools's multi-purpose building and the school entrance roof supported by rainwater harvesting (RWH) (1 roof) and b) a low green shelter (NBS3) at the east side of the school supported by greywater recycling (GWR)
Simulation Period: 01/11/2014 - 12/07/2021
Impervious area (m2) | 1580.56 |
Green roof permeable pavement (m2) | 184.0 |
Rainwater Harvesting roofs (m2) | 350.7 |
Semi-intensive green roof (m2) | 45.0 |
Extensive green roof (m2) | 113.7 |
Planters (m2) | 6.0 |
Green shelter (m2) | 269.3 |
Rainwater Harvesting Tank capacity (L) | 10000.0 |
Greywater Tank capacity (L) | 2000.0 |
Month | NBS 1 Water Autonomy (%) | NBS 3 Water Autonomy (%) | Total NBS Water Autonomy (%) |
1 | 100.00 | 94.17 | 96.33 |
2 | 100.00 | 100.00 | 100.00 |
3 | 100.00 | 100.00 | 100.00 |
4 | 89.30 | 71.72 | 78.24 |
5 | 42.44 | 94.03 | 74.90 |
6 | 47.29 | 96.09 | 77.99 |
7 | 29.28 | 38.11 | 34.83 |
8 | 10.89 | 0.00 | 4.04 |
9 | 9.22 | 70.68 | 47.89 |
10 | 59.03 | 100.00 | 84.84 |
11 | 94.20 | 100.00 | 97.85 |
12 | 100.00 | 100.00 | 100.00 |
EI-45 (ENV) | Site NBS Water Autonomy (%) | 59.45 |
EI-46b (ENV) | Water Reuse (%) | 9.33 |
EI-46a (ENV) | Potable Water Savings (%) | -6.98 |
EI-44 (ENV) | Energy Consumption (kWh/year) | 216.07 |
EI-50 (ENV) | Runoff coefficient (%) | 57.47 |
EI-48b (ENV) | Stormwater treated/managed locally (%) | 19.34 |
EI-48a (ENV) | Wastewater treated/managed locally (%) | 7.53 |
CI-55 (ENV) | Impervious Surfaces (%) | 66.57 |
EI-67 (URB) / CI-66 (ENV) | Green Surfaces/Spaces (%) | 33.65 |